Browse Prior Art Database

HTHP Filtrate Cell Barite Sag Test

IP.com Disclosure Number: IPCOM000202384D
Publication Date: 2010-Dec-14
Document File: 4 page(s) / 174K

Publishing Venue

The IP.com Prior Art Database

Abstract

The HTCST offers a viable alternative to attain sag rate information at the well on a daily to semi-weekly basis.

This text was extracted from a PDF file.
This is the abbreviated version, containing approximately 30% of the total text.

Page 01 of 4

HTHP Filtrate Cell Barite Sag Test 

 

The path to a field‐ready test that can monitor the health of a drilling fluid with respect to suspending  barite has been quite eventful.  Reliable methods have been identified over time, but the trend has been  toward higher complexity and newer techniques that often require the amenities of a drilling fluids  laboratory.  Keeping the mud lab on location in mind, a new static test procedure has been designed to  aid in predicting sag events and making sound fluid treatment decisions to help prevent them. 
 
Based on the sag factor1 methodology, the HTHP Filtrate Cell Barite Sag Test (HTCST) allows rigsite  personnel to continuously assess changes in fluid density over time and at temperature.  The standard  sag factor test is equipment‐intensive, that can make it impractical for field use.  Personnel performing  the test should have careful technique, or the results can be subject to variability.  This may be due to  the subjective removal of top and middle portions of the column, mixing during separations, entrapped  air in measured samples and the small volume measured - usually only 10 milliliters.  In spite of the  limitations, this method has gained broad acceptance for laboratory use. 
 
The HTCST offers a viable alternative to attain sag rate information at the well on a daily to semi‐weekly  basis.  Using the filtrate cell Mud Balance pictured in Figure 1, mud engineers on location can gauge the  effects of temperature on the active system with accurate and repeatable results.  The cup with  threaded pull rod device is placed in a full‐size HTHP filtrate cell, and the cell filled with an appropriate  volume of fluid.  The cell is heated and pressurized for the desired time interval.  After the cooling and  venting, the Mud Balance lid is lowered into place on the pull rod and the balance pulled from the cell.   The bottom one hundred milliliters of fluid is captured with minimal disturbance and can then be  weighed on a standard top‐loading or triple beam balance to obtain the final density. 

 

(This page contains 00 pictures or other non-text object)

(This page contains 01 pictures or other non-text object)

 

Figure 1: Filtrate cell Mud Balance   

Comparing the new method to the lab‐based sag factor has shown similar results may be obtained,  provided the pressure in the cell is maintained at the set level.  The efficiency of design offered by the  HTCST can allow the user to make a much more rapid determination of the sag rate and to take further  action if necessa...